Systemtechnik Hoelzer GmbH - Logo

 Distributor | References | Contact

Precision Laser Tool-Control Station

 

Laser_Kalibrierstation_300

icn_pdf04

Technical Specifiactions
Format: .pdf

icn_mail

request information
material

Specifications:

 

Type

sealed laser tool-control unit with, airflow self-cleaning lense

Object Recognition

min 0,01 mm (depending on modell)

Repeat Accuracy

< 3 µm (depending on model)

Supply

5 VDC ± 0,5 V. Max. 50 mA

Housing

anodized alloy

Laser beamlength

670 mm max; visible red

Laser Protection Category

1 (no specific protective measures necessary)

Connector Out

npn, open Kollektor; > 10KHz, max. 5 mA

Protection Class

IP54

Connection

round - plug or wires

Mounting

M4 4 Positions

Weight

ca. 100g (without cable)

Pneumatics

hose connector (M5 thread); 0,5 - 4 Bar

 

Operation data:

Supply Current

5V ± 0,5 V, max 50 mA

 

Switch Frequency

> 10 kHz

 

OUT

beam interrupted : 0 V
beam free: TTL-High

see table

Reference-Out

monitoring of threshold
voltage possible 

see table

Connector

5 pins
+ Ub, GND, signal, reference,
select

standard-sensor-plug /wire 0,5 m (pin-assignment see table below)

Purpose of the select-input:

The laser beam will not switch-on unless the select-input is connected to 0 V liegt In case the select-input is connected to 5 V, the laser-beam will extinguish.
 

Select

Laser-Beam

npn-open collector

LED

0 V

interrupted 

0 V

off

0 V

free

> 2,8 V(TTL-High)

on

5 V

off

High

off

NC

off

High

off

Effect of the reference-current

With the trimmer, the reference-current for the measuring tolerance of the laser can be adjusted. Thereby a deviation of the measured diameter from the reference diameter will be compensated. The reference-current is accessible for trimming from outside the laser housing.

Reference-Current

Effect

Rotation
Trimmer

Diameter
Compensation

2,5 V

measured diameter increases

clockwise

+ 50 µm / V

1,2 V

default setting

-

0 µm

0 V

measured diameter decreases

reverse-clockwise

- 50 µm / V

Wiring:

Signal

Type

Wire Color

+ Ub (5V)

Power

braun 

GND

Power

green

OUT

out

white

Reference´

out

grey

Select

out

yellow

Pneumatics:
  • hose connection with M5-thread
  • dry, dust-free compressed air
  • max. 4 bar

 

Mechanical mounting:
  • customer specific